info@ofisistelec.com   |  (+34) 96 144 50 55   |

Módulo esclavo Profinet con capacidad para soportar hasta 8 módulos de expansión de la serie CTH 300 (E/S digitales. E/S analógicas, módulo temperatura, módulo PID). Soporta Profinet Master de Siemens, incluyendo S7-300, 400, 1200 y 1500.

Physical properties
Size(W×H×D) 34×115×100mm mm
Power loss
Rated input voltage 24V DC
Input voltage range 20.4V~28.8V DC
Input current 0.8A
Bus power supply voltage +5V DC
Bus supply current 1.6A
Isolation External power supply is isolated from system power supply
Power protection The power supply end provides the reverse connection protection function and the surge absorption function
LED indicator characteristics
24V power indicator (green) ON = 24VDC power supply is normal
OFF = No 24VDC power supply
SF indicator light (red) ON = extended I/O bus failure or PROFINET module failure
OFF = No error
BF indicator light (red) ON = PROFINET bus communication failure (no connection to switch, no network detected)
Blinking=Inconsistent hardware configuration
OFF = No error
MT indicator light (yellow)(Maintenance indicator light)

 

Reserved
Indicator light (green) ON = There is a connection to the switch /PN master
OFF =No connection to switch /PN master
Indicator light (yellow) ON = data receiving and receiving to switch /PN master station
OFF = No data transceiver to switch /PN master station
EetendI /O capabilities
Maximum number of modules supported per slave 8(can be added digital , analog and temperature module, HSC,HSP module, other types of module are not included)
Protocol type CTH300 PLC custom 55MHz bus protocol
Topology Support star, tree, linear, ring
PROFINET communication port
Communication port 1 dual RJ45 port
Data transmission rate Ethernet with a transmission rate of 10Mbps
The PROFINET transmission rate is 100Mbps, full duplex
Supported Ethernet services Ping, ARP, Network Diagnostic (SNMP)/MIB-2, LLDP
Sending cycle 250us~4ms
Third-party PROFINET master station Support
Longest communication distance from station to station 100m(100BASE-TX)
Topology Supports star, tree, linear and ring topologies
Isolation Communication port isolation
Hardware configuration function
Import file type Profinet GDS file XML format
Third-party PN master station The addition of the CTH3 PNT-000S1 module supports the expansion of 8 slots
Expansion module can add digital, analog and temperature module, HSC,HSP module, other types of module are not included

También te puede interesar…

Título

Ir a Arriba